Linde offers a wide range of high purity carrier, purge and detector gases. With process applications, instrument grade gases are commonly used for analytical work. For quality control and R&D analysis, a higher quality detector gases may be appropriate.
Our instrumentation gas finder offers suggestions for the respective instruments. Please note that purity and gas specifications may differ depending on instrument manufacturer. Contact the HiQ Team if you need precise information about the gas requriements for your analyser.
Instrumentation Gas Finder - Listing
Instrumentation | Impurity | Carrier (C) / Purge (P) | Recommendations | ||
Concern |
& Detector (D) Gases (+ min. purity requirement) |
Regulators |
Generators |
||
Flame |
THC, H2O, O2 |
C/P: D: |
HiQ Helium 5.0 |
BL C106 series BL C106 series BL C106 series BL C106 series BL C106 series |
HiQ H2 FID HiQ N2 SIROCCO HiQ H2 FID* HiQ Zero Air* |
Thermal Conductivity Detector (TCD) |
THC, H2O, O2 |
C/P: |
HiQ Argon 5.0 HiQ Helium 5.0 HiQ Hydrogen 5.0 HiQ Nitrogen 5.0 |
BL C106 series RL C200 series BL C106 series BL C106 series |
HiQ H2 FID HiQ N2 SIROCCO |
Electron Capture Detector (ECD) |
THC, |
C/P: D: |
HiQ Helium 5.0 Zero HiQ Nitrogen 5.0 Zero HiQ Hydrogen 5.0 Zero HiQ Nitrogen 5.0 ECD 5 or 10% Methane / Argon 5.0 HC free |
RL C200 series RL C200 series RL C200 series RL C200 series RL C200 series |
HiQ N2 SIROCCO HiQ H2 CARRIER HiQ N2 SIROCCO |
Nitrogen |
NH3, Amines |
C/P: D: |
HiQ Argon 5.0 HiQ Helium 5.0 HiQ Hydrogen 5.0 HiQ Nitrogen 5.0 HiQ Hydrogen 5.0 HiQ Synthetic Air 5.0 |
BL C106 series BL C106 series BL C106 series BL C106 series BL C106 series BL C106 series |
HiQ H2 FID HiQ N2 SIROCCO HiQ H2 FID HiQ Zero Air |
Photo |
THC |
C/P: D: |
HiQ Helium 5.0 Zero |
BL C106 series BL C106 series BL C106 series RL C200 series BL C106 series |
HiQ N2 SIROCCO HiQ Ultra Zero Air HiQ N2 SIROCCO |
Fourier Transform Infrared Spectroscopy (FTIR) |
H2O, THC, HC |
C/P: |
HiQ Nitrogen 5.0 HiQ Helium 5.0 |
BL C106 series RL C200 series |
HiQ N2 SIROCCO |
Pulse Discharge Photo Ionization Detector (PDPID) |
C/P: |
HiQ Helium 6.0 |
RL C200 series |
||
Atomic Absorption Spectrometry (AAS) |
H2O, H2S, PH3 |
D: |
HiQ Synthetic Air 5.0 HiQ Nitrous Oxide 2.0 AAS HiQ Acetylene 2.6 AAS |
BL C106 series BL C106 series BL C106 series |
HiQ Ultra Zero Air |
Atomic Absorption Spectrometry Graphite furnance (GF-AAS) |
D: |
HiQ Argon 5.0 |
BL C106 series |
||
Inductively Coupled Plasma Spectrophotometer (ICP) |
D: |
HiQ Argon 5.0 |
BL C106 series |
* Gas Generators:
The HiQ H2 Air FID station has been designed to feed GC's with Hydrogen and Zero Air at the same time.